AS568 · ISO 3601 · MIL-PRF cross-references, 15 compounds
Company · quality

Quality and testing

What we measure, on which lots, and what travels with the shipment. No badges we have not earned — if a certificate is required for your part, tell us which one and we will say whether we can issue it or whether it has to come from a third-party laboratory.

01On every production lot

PropertyMethodWhy it is there
HardnessShore A, ASTM D2240The single fastest indicator that a batch was mixed correctly.
Tensile strengthASTM D412Catches under-cure and filler errors that hardness alone misses.
Elongation at breakASTM D412Together with tensile, defines the compound against its datasheet.
Compression setASTM D395, method BThe property that actually decides seal life at temperature.
Specific gravityASTM D297Detects loading errors and compound substitution.
DimensionsOptical or contact, per drawingID, CS and OD against the tolerance band on the drawing.
Vernier caliper measuring the outside diameter of an O-ring
Outside diameter is measured, not assumed.
Batches of O-rings in polythene bags on a packing table
Bagged by dash number and lot, so a batch can be traced back.

02What ships with the parts

Certificate of conformity

States the compound, the standard revision and the designations the parts were made to — including both the old and the current designation where one superseded the other.

Batch record

Compound batch, cure date and lot number, kept for seven years. That is what makes a traceability question answerable two years later.

Test report

The physical properties measured on the lot, against the compound datasheet. Available for any shipment on request, and quoted as standard on qualification lots.

Third-party testing

Where a customer's qualification requires an accredited laboratory, we send samples out and quote the cost with the parts. We do not issue certificates we are not entitled to issue.

03Standards we work to

Size dimensions follow AS568 for inch parts and ISO 3601-1 for metric parts. Surface acceptance follows ISO 3601-3 unless the drawing specifies otherwise. Material callouts follow the customer's drawing, or ASTM D2000 line callouts where the drawing cites them. Military designations are made to the document the designator names, where we can obtain that document.