An AS568 dash number is not a metric size with a different name. The two systems were built independently, they round differently, and their tolerances are specified on different principles. A cross-reference table that maps dash numbers to "nearest" metric sizes is useful for identifying a part in your hand; it is not a basis for designing a gland.

How each system defines a size
AS568 defines O-rings by dash number, in inches. The dash number encodes a series (by cross-section) and a sequence within that series. There are 369 standard sizes, in five cross-section series plus a group of boss gaskets:
| Series | Cross-section | Sizes |
|---|---|---|
| 000 | 0.070 in (1.78 mm) | 50 |
| 100 | 0.103 in (2.62 mm) | 77 |
| 200 | 0.139 in (3.53 mm) | 84 |
| 300 | 0.210 in (5.33 mm) | 87 |
| 400 | 0.275 in (6.99 mm) | 51 |
| 900 | boss gasket sections | 20 |
ISO 3601-1 defines O-rings by inside diameter d1 and cross-section d2, both in millimetres, with a size designation written as d1 × d2. The standard includes both a preferred series of metric sizes and a table of inch sizes that corresponds to AS568 — which is the source of most of the confusion, because the inch table in ISO 3601 is a restatement of AS568 in metric units, not a set of interchangeable metric parts.
JIS B2401 is a third system, with its own P, G and S series, used widely in Japanese equipment. Its sizes overlap ISO 3601 in places and not in others.
The worked example
Take AS568-214: 0.984 in ID × 0.139 in CS. In metric that is 24.99 mm × 3.53 mm.
The nearest ISO 3601 metric size is 25 × 3.5 mm. The differences — 0.01 mm on the ID and 0.03 mm on the cross-section — look negligible. They are not, for three reasons:
- Tolerance bands are not the same width. The AS568 ID tolerance for this size is ±0.007 in (±0.18 mm). An ISO 3601 metric 25 mm ring carries its own tolerance, which may be tighter or looser and is defined differently.
- The cross-section difference changes the squeeze. A 3.50 mm section in a groove designed for 3.53 mm has 0.85 % less material — small, but it moves the squeeze calculation in the same direction as a groove depth error.
- Nobody's drawing is nominal. The groove was designed for one system's tolerance band, and the seal must sit inside it with margin. Mixing systems consumes that margin before the seal is even installed.
When a cross-reference is legitimate
A cross-reference is legitimate when the two rings are dimensionally equivalent within the tolerance bands of both systems for both ID and cross-section. In practice:
- For identification — "this ring measures 24.99 × 3.53 mm, so it is an AS568-214" — fine, provided you measure properly and check the tolerance.
- For a low-pressure water joint with a generous groove — usually acceptable, because the squeeze band is wide and the consequence of a small error is a drip, not a failure.
- For a hydraulic joint at pressure, a gas joint, or anything with a military or aerospace designation — not acceptable without an engineering check of the gland against the actual part tolerance.
cross-reference the part, never the design. If the drawing says AS568-214, the seal is AS568-214. If the metric equivalent is the only thing available, the groove dimensions and the squeeze have to be re-checked, and the drawing has to be changed to say so.
The military designators, and why they are not sizes either
A dash number identifies a size. It does not identify a compound, a hardness, or a specification. That is what the military designator does, and it is the reason MS28775-214, M83248/1-214 and AS3209-214 are three different parts that all fit the same groove:
| Designator | Compound | Note |
|---|---|---|
| MS28775-214 | NBR, 70 Shore A | The classic nitrile part |
| M83248/1-214 | FKM, 75 Shore A | Fluorocarbon equivalent |
| AS3209-214 | FKM | Aerospace specification, later revision |
| M25988/1-214 | FVMQ | Fluorosilicone for low temperature and fuel |
This is the professional trap in cross-referencing: the size crosses over, the material does not. A customer who asks for "the metric equivalent of M83248/1-214" is asking for a fluorocarbon ring of that size to a different specification, and the answer depends on which properties matter — hardness, compression set, fluid resistance, or the paper trail.
How to build a cross-reference you can defend
- Measure the part, not the label. ID, cross-section, and where possible the hardness. A caliper on a used ring reads low because the ring is flattened.
- Convert to both units and compare against both standards' tables, not against a single "equivalent" column.
- Check the tolerance bands overlap. If the AS568 ring's ID band and the ISO ring's ID band do not overlap, they are not equivalent, whatever the nominal numbers say.
- Check the cross-section separately. A size can match on ID and miss on CS, or vice versa. Both have to land.
- Record the source of the data. A cross-reference table without a source is a rumour.
Why this matters commercially
Most cross-reference errors are found at the worst time: a machine is down, the OEM part is a week away, and the local supplier has "the metric equivalent". It fits, it seals for a while, and then it fails — because the compound is different, or the cross-section was 0.03 mm thin, or the tolerance band put the squeeze at the edge.
The safe version of that rescue is to take the measurement, check the compound against the actual media, and confirm the groove dimensions against the substitute's actual tolerance. It takes twenty minutes and it is the difference between a repair and a repeat failure.
Frequently asked questions
Is AS568-214 the same as a 25 × 3.5 mm O-ring?
Dimensionally very close — 24.99 × 3.53 mm — but not the same part. The tolerances are defined by different standards and the cross-section differs by 0.03 mm, which changes the squeeze. Use it as an identification, not as a substitution.
How many AS568 sizes are there?
369 standard sizes from -001 to -932, across five cross-section series plus 20 boss gasket sizes. The full table is available as a CSV on this site.
Can I use a metric O-ring in an AS568 groove?
Often yes at low pressure, if the cross-section matches within about 0.05 mm and the ID tolerance band overlaps. For pressure or gas service, re-check the squeeze and the clearance before substituting.
Why is the metric equivalent always slightly different?
Because AS568 was defined in inches with inch-based tolerances, and the metric sizes were defined independently in round millimetre values. The conversion is not exact by construction, and the standards do not intend it to be.
Does ISO 3601 cover the AS568 sizes?
ISO 3601-1 includes a table of inch sizes that corresponds to AS568, expressed in millimetres. That table identifies the sizes; it does not make the metric series interchangeable with them.